TESCOM™ REGULUS 4 DUAL STAGE REGULATOR

Regulus 4 dual-stage pressure reducer, with an integrated relief valve, is extremely sensitive (mbar range) for gas purity up to 5.0. Ideal for use as an in-line pressure reducer. Suitable for non-corrosive gases, oxygen service and commonly used in production testing.

Download :
TESCOM REGULUS 4

Specifications

FLUID MEDIA Non-corrosive gases up to gas purity 5.0 (99.999 Vol %)
Maximum Inlet Pressure 290 psig / 20.0 bar
Outlet Pressure Ranges 0.07-0.73 psig / 5-50 mbar
0.73-7.25 psig / 50-500 mbar
2.9-22 psig / 0.20-1.5 bar
14.5-58 psig / 1.00-4.0 bar
Nominal Flow Max. 72 (m3/h air)
Operating Temperature -4°F to 158°F / -20°C to 70°C
Body Aluminum
Diaphragm Butyl Rubber with PTFE coating
Seat NBR
Port Types and Sizes Inlet:
Adapter: M16 x 1.5
Body: G 3/4″
Outlet: G 1 1/4″
Gauge: G 1/2″
Relief Valve: L12, DIN 3853 (M18 x 1.5 + cone)
Connections See Part Number Selector
Weight 9.3 lbs / 4.2 kg